YTI inventory image. Contact YTI to confirm the exact physical unit, flange configuration, heaters, condition and included hardware before purchase or rental.
Varian · High-Vacuum Equipment
Varian HS-35 Diffusion Pump
Model: HS-35 · Equipment: Diffusion Pump
Large industrial Varian HS-35 diffusion pump available from YTI for purchase or rental. Built for high-throughput vacuum coating, furnace, processing and production applications requiring substantial high-vacuum pumping capacity.
Pricing
Final pricing depends on the selected unit, condition, configuration, refurbishment scope and freight.
In Stock
- 1 Varian HS-35 immediately available
- 3 additional units available within approximately 2 weeks
- Available for purchase or rental
What do you need? Select an option to start the correct quote request.
Product Description
Varian HS-35 high-vacuum diffusion pump
The Varian HS-35 is a large industrial oil diffusion pump designed for applications that require substantial high-vacuum pumping capacity and dependable operation in production environments.
Pumps in the HS-35 family have been used in vacuum coating, metallizing, optical coating, vacuum furnaces, heat treatment, thin-film processing and other industrial vacuum systems where high gas throughput and large chamber volumes are common.
YTI currently has HS-35 equipment available for purchase and rental. One unit is immediately available, with additional pumps expected within approximately two weeks.
Because HS-35 pumps may have been produced in different configurations or modified during years of industrial use, YTI confirms the actual flange arrangement, heaters, electrical configuration, cooling, internal condition and included hardware before the physical pump is quoted.
YTI also supports customer-owned HS-35 pumps through complete refurbishment. That service includes teardown, cleaning, jet-stack inspection, heater evaluation, resealing, fresh application-correct pump fluid, helium leak testing and performance verification before return to service.
HS-35 Factory-Reference Specifications
| Manufacturer | Varian / Agilent |
|---|---|
| Model Family | HS-35 / NHS-35 |
| Equipment Type | Oil Diffusion Pump |
| Air Pumping Speed | 28,000 L/s |
| Helium / Hydrogen Speed | 35,000 L/s |
| Operating Range | 9 × 10⁻⁴ to <5 × 10⁻⁸ Torr |
| Maximum Throughput | 25 Torr-L/s |
| Maximum Forepressure — Full Load | 0.40 Torr |
| Maximum Forepressure — No Load | 0.55 Torr |
| Recommended Backing Pump | ≥300 CFM / 510 m³/hr |
| Fluid Charge | 3 U.S. gal. / 11.3 L |
| Electrical | 3 phase · 50/60 Hz |
| Common Factory Voltages | 240 / 415 / 480 VAC |
| Pump Power | 24,000 W |
| Cooling Water | 4 GPM at approximately 60–80°F |
| Factory Fluid Reference | DC-704 |
| Inlet Flange | 35 in. ASA or ISO 1000F |
| Foreline | 6 in. ASA or ISO 200K |
| Factory Pump Weight | Approx. 1,500 lb / 680 kg |
| Current YTI Availability | 1 now · 3 additional approximately 2 weeks |
These are factory-reference specifications for the HS-35 / NHS-35 family. The exact YTI inventory unit may differ by production year, flange arrangement, heaters, electrical configuration, modifications or prior refurbishment. Confirm the physical equipment with YTI before installation or system design.
Before You Purchase
Confirm the HS-35 matches the complete vacuum system
01 · INLET
Verify the chamber connection
Confirm inlet flange style, bolt pattern, chamber interface and physical installation dimensions before choosing a replacement pump.
02 · ELECTRICAL
Confirm heater power
Verify facility voltage, heater configuration, controls and safety interlocks before connecting the HS-35.
03 · COOLING
Check water capacity
Large diffusion pumps depend on stable cooling-water flow through the pump body and associated baffle or cold-cap hardware.
04 · BACKING
Size the backing pump
The mechanical backing stage must maintain acceptable forepressure and handle the chamber’s actual process gas load.
05 · BAFFLE / TRAP
Review vapor control
Baffles, cold caps and traps affect backstreaming, conductance, contamination control and pumping performance at the chamber.
06 · CONDITION
Confirm refurbishment scope
YTI can inspect the body, internal jet assembly, heaters, seals, cooling system and pump fluid before return to service.
Equipment Options
Purchase, rent or refurbish a Varian HS-35
Current Inventory
Purchase an HS-35
YTI has current HS-35 inventory available. YTI can confirm the exact equipment, configuration, condition, refurbishment requirements and freight before providing final pricing.
Request purchase pricing →Temporary Equipment
Rent an HS-35
Ask about HS-35 rental availability when production needs to continue while another pump is being repaired, rebuilt or prepared for replacement.
Request rental availability →Existing Equipment
Refurbish your HS-35
YTI provides complete diffusion-pump refurbishment including teardown, cleaning, internal inspection, heater verification, resealing, new pump fluid, leak testing and performance verification.
View refurbishment service →Technical Support
More Varian and diffusion-pump support from YTI
Product FAQs
Varian HS-35 diffusion pump questions
Does YTI currently have a Varian HS-35 diffusion pump available?
Yes. YTI currently lists one Varian HS-35 as immediately available, with three additional units available within approximately two weeks. Inventory should be reconfirmed when requesting a quote.
Is the Varian HS-35 available for sale or rental?
Yes. YTI currently offers the standalone HS-35 diffusion pump for both purchase and rental. Terms depend on the selected equipment, timing, configuration and application.
What is the pumping speed of a Varian HS-35?
Factory specifications for the NHS-35 / HS-35 family list an air pumping speed of approximately 28,000 liters per second and approximately 35,000 liters per second for helium and hydrogen. Installed performance depends on the complete vacuum system.
How much electrical power does an HS-35 require?
Factory specifications list approximately 24 kW of pump power with three-phase electrical service. Common factory configurations include 240, 415 and 480 VAC. YTI should verify the exact heater configuration before installation.
How much cooling water does an HS-35 require?
Factory-reference specifications list approximately 4 gallons per minute of cooling-water flow at approximately 60–80°F. Connected baffles, traps and other equipment may have additional cooling requirements.
What backing pump is recommended for a Varian HS-35?
Factory specifications recommend at least approximately 300 CFM of backing capacity. Actual requirements depend on the process, chamber volume, gas load and foreline design.
What diffusion pump fluid does the HS-35 use?
Factory literature references DC-704 and an approximately three-gallon fluid charge for the NHS-35 family. YTI should confirm the appropriate fluid for the physical pump and the intended process before service.
Can YTI rebuild an existing Varian HS-35?
Yes. Diffusion-pump refurbishment is a core YTI service. The rebuild process can include teardown, cleaning, jet-stack inspection, boiler and heater verification, new seals and gaskets, fresh pump fluid, helium leak testing and performance verification.
Can YTI support older Varian or current Agilent vacuum equipment?
Yes. YTI supports legacy Varian and current Agilent diffusion pumps, gauges, controls, leak detectors and connected vacuum equipment through refurbishment, troubleshooting, replacement components, rentals and system integration.
How do I know whether the HS-35 will fit my system?
Send YTI the existing pump model, nameplate photos, chamber connection, flange dimensions, electrical information, cooling requirements, backing-pump model, process application and photos of the current installation. YTI can review compatibility before the replacement pump is prepared.
Need a Varian HS-35?
YTI has current HS-35 inventory for purchase and rental. Send your system information to confirm the right unit, configuration, condition and pricing.